ASTM E1491-97 Digital PDF

$37.00

Standard Test Method for Minimum Autoignition Temperature of Dust Clouds
standard by ASTM International, 09/10/1997

Document Format: PDF

Description

1.1 This test method determines the minimum temperature at which a given dust cloud will autoignite when exposed to air heated in a furnace at local atmospheric pressure.

1.2 Data obtained from this test method provide a relative measure of dust cloud autoignition temperatures.

1.3 This test method should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions. However, results of this test method may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Product Details

Published:
09/10/1997
Number of Pages:
9
File Size:
1 file , 190 KB
Note:
This product is unavailable in Russia, Ukraine, Belarus